Hypersensitivity Pneumonitis II, (Farmer's Lung Panel)


Sunquest Code:HYPNU  
Epic Code:LAB6022Epic Name:Hypersens Pneumonitis II
Synonyms:Allergic Lung Serology; Farmer's Lung Panel; Pneumonitis, Hypersensitivity
Methodology:Immunodiffusion
CPT Code:86331 x3, 86606 x3
Turnaround Time:Specimens are sent to reference laboratory Mon-Sat; results are reported in 3-5 days.
Compliance:

Analyte Specific Reagent. This test was developed and its performance characteristics determined by ARUP Laboratories. The U. S. Food and Drug Administration has not approved or cleared this test; however, the FDA has determined that such clearance or approval is not necessary.



Collection Instructions

Specimen:Blood
Optimal Volume:2 mL
Minimum\Peds Volume:0.5 mL
Container:Red or gold (gel) (Red (no gel))
Causes for Rejection:Plasma


Processing and Shipping

Specimen Processing:Centrifuge and aliquot within two hours of collecton, 1 mL, 0.15 mL minimum. Store in refrigerator.
Shipping Instructions:Ship at refrigerated temperature.
Test Performed at or Referral Lab Lab Sendouts  (ARUP)
Referral Lab number:55226


Interpretive

Reference Range:

Aspergillus flavus: None detected

Aspergillus fumigatus #2: None detected

Aspergillus fumigatus #3: None detected

Saccharomonospora viridis: None detected

Thermoactinomyces candidus: None detected

Thermoactinomyces sacchari: None detected.

 

 

Use:Precipitating antibodies against the offending antigen can be demonstrated in most active cases of hypersensitivity pneumonitis. However, a positive test does not always indicate active disease since asymptomatic individuals may develop precipitins without any features of hypersensitivity. A positive test is a helpful diagnostic tool when supported by historical and clinical evidence. The absence of a positive test does not rule out hypersensitivity pneumonitis.