C7 Function Assay


Sunquest Code:C7F  
Epic Code:LAB6275Epic Name:Complement C7 Function
Methodology:Hemolytic assay
Turnaround Time:Specimens are sent to reference laboratory Mon-Thur; results are reported within 4 weeks.


Collection Instructions

Specimen:Blood
Optimal Volume:2.2 mL
Container:Red (no gel)
Causes for Rejection:Thawed specimen. Samples stored at -20°C. Gel barrier tubes are not acceptable.


Processing and Shipping

Specimen Processing:Allow specimen to clot at room temperature for 20-60 minutes. Centrifuge and aliquot 1 mL minimum within 2 hours of collection or ASAP. Store on dry ice or at -70°C.
Shipping Instructions:Ship overnight on dry ice.
Stability:1 year if frozen at -70°C.
Test Performed at or Referral Lab Lab Sendouts  (National Jewish Health)
Referral Lab number:C7F


Interpretive

Reference Range:12327-33836 Units/mL


Click HERE to Report test errors or omissions.
*If no email program is associated with this computer, please contact:
systemlabguide@fairview.org for TestID: 4681"