Adenovirus, Qualitative PCR


Sunquest Code:ADVPCR  
Epic Code:LAB6656Epic Name:Adenovirus, Qualitative PCR
Methodology:Real-time polymerase chain reaction
Turnaround Time:Specimens are sent to reference laboratory Mon-Sat; results are reported within 1-4 days.
Special Instructions:Specimen source is required.
Compliance:

Analyte Specific Reagent. This test was developed and its performance characteristics determined by ARUP Laboratories. The U. S. Food and Drug Administration has not approved or cleared this test; however, the FDA has determined that such clearance or approval is not necessary.



Collection Instructions

Specimen:Blood, bronchoalveolar lavage (BAL), CSF, nasopharyngeal swab, sputum or tissue
Optimal Volume:2 mL
Minimum\Peds Volume:1.2 mL
Container:Red (no gel) (Sterile tube, Plastic leakproof container, sterile, Container, Tissue, sterile, Red or gold (gel), Virology containers)
Causes for Rejection:Heparinized specimens.


Processing and Shipping

Specimen Processing:Do not process BAL, CSF, sputum or tissue. Centrifuge and aliquot 1 mL; 0.5 mL minimum serum. Store frozen.
Shipping Instructions:Ship frozen.
Test Performed at or Referral Lab Lab Sendouts  (ARUP)
Referral Lab number:2007473


Interpretive

Reference Range:By report.


Click HERE to Report test errors or omissions.
*If no email program is associated with this computer, please contact:
systemlabguide@fairview.org for TestID: 5493"