Endomysial Antibody, IgA by IFA
Abbrev Code: | ENDIGA | ||
Order Code: | LAB6971 | Order Name: | Endomysial Antibody, IgA by IFA |
Synonyms: | Endoreticulin Antibody Panel; Celiac Disease; Coeliac Disease; Malabsorption | ||
Methodology: | Indirect fluorescent antibody | ||
CPT Codes: | 86231 x1, 86231 x1 | ||
Turnaround Time: | Specimens are sent to reference laboratory Mon-Sat; results are reported in 2-6 days. |
Collection Instructions
Specimen: | Blood |
Optimal Volume: | 2 mL |
Minimum\Peds Volume: | 0.5 mL |
Container: | Red or gold (gel) Alternate Containers: Red (no gel) |
Causes for Rejection: | Plasma. Severely lipemic, contaminated or hemolyzed specimens. |
Processing and Shipping
Specimen Processing: | Separate serum from cells ASAP or within 2 hours of collection. Centrifuge and aliquot 1 mL, 0.15 mL minimum. Store in refrigerator. |
Shipping Instructions: | Ship at refrigerated temperature. |
Stability: | After separation from cells: 48 hours at room temperature; 2 weeks refrigerated; 1 year frozen. |
Test Performed at or Referral Lab | Lab Sendouts (ARUP) |
Referral Lab number: | 50736 |
Interpretive
Reference Range: | Less than 1:10 |
Use: | Acceptable single screening test for IgA-competent individuals with suspected celiac disease. May aid in monitoring adherence to gluten-free diet in celiac disease confirmed patients. |