Granulocyte Colony Stimulating Factor
Abbrev Code: | GCSFB | ||
Order Code: | LAB6616 | Order Name: | Granulocyte Colony Stim Factor, Blood |
Synonyms: | G-CSF; GCSF; Cytokines | ||
Methodology: | Enzyme-linked immunosorbent assay | ||
CPT Codes: | 83520 x1 | ||
Turnaround Time: | Performed Mon-Fri; results are reported within 5 working days. | ||
Compliance: | Commercial kit validated by the testing laboratory, but not FDA approved for diagnostic use. |
Collection Instructions
Specimen: | Blood |
Optimal Volume: | 2 mL |
Minimum\Peds Volume: | 1.2 mL |
Container: | Red (no gel) Alternate Containers: Purple (EDTA) |
Causes for Rejection: | Gross hemolysis, stored at room temperature >6 hours |
Processing and Shipping
Specimen Processing: |
Serum: Allow samples to clot for 30 minutes from time of collection. Centrifuge for 15 minutes at 1000-1500 g (rcf) at room temperature.
Plasma: Plasma specimens must be processed immediately. Centrifuge for 15 minutes at 1000-1500 g (rcf) at room temperature.
Aliquot into two vials with 250 uL per vial. Freeze immediately at ≤-20°C (-70°C preferred). Contact Cytokine Lab if there is adequate sample for only one vial.
|
Shipping Instructions: | Ship on dry ice. |
Test Performed at or Referral Lab | Lab Sendouts (UMCytokine) |
Interpretive
Reference Range: |
|
Click HERE to Report test errors or omissions.
*If no email program is associated with this computer, please contact:
systemlabguide@fairview.org for TestID: 645"