Fentanyl and Metabolite, Urine, Quantitative


Abbrev Code:ARMISC   
Order Code:LAB4909Order Name:Send Outs Misc Test
Methodology:Liquid chromatography/Tandem mass spectrometry
CPT Codes: 80354 x1
Turnaround Time:Specimens are sent to the reference laboratory Mon-Sat; results are reported within 1-4 days.
Compliance:

This test was developed and its performance characteristics determined by ARUP Laboratories. It has not been cleared or approved by the U.S. Food and Drug Administration. This test was performed in a CLIA certified laboratory and is intended for clinical purposes.

Associated Links:

Urine Collection Procedure



Collection Instructions

Specimen:Urine, random collection
Optimal Volume:Submit entire collection; analysis requires 0.5 mL.
Container:Plastic leakproof container, sterile
Causes for Rejection:Specimens exposed to repeated freeze/thaw cycles.


Processing and Shipping

Specimen Processing:Aliquot 4 mL, 0.5 mL minimum. Store at room temperature.
Shipping Instructions:Ship at room temperature.
Stability:1 month at room temperature or refrigerated.
Test Performed at or Referral Lab Lab Sendouts  (ARUP)
Referral Lab number:92570


Interpretive

Reference Range:Negative.

Cutoff for positive is 1.0 ng/mL or greater
Use:Detection of fentanyl use or abuse.


Click HERE to Report test errors or omissions.